Concrete Block & CMU Wall Calculator

To calculate concrete blocks for a CMU wall, multiply wall length by height in feet and multiply by 1.125 blocks per square foot (each 8×8×16 block covers 0.888 sq ft). A 20×4 ft wall (80 sq ft) requires 90 blocks (95 with a 5% cutting waste margin), 3 bags of 80 lb Type S mortar, and ~9 bags of core fill grout when rebar is spaced every 32 inches on center.

Verified Spec
|Source: ASTM C387 & ACI 302.1R|Updated: Sep 2026|✓ Peer-reviewed
Wall Presets:

Wall Dimensions

ft
Max 4' DIY
ft
+5%
Total Blocks Required
95Blocks(6 courses · ~15 per row)

3 bags mortar•80 sq ft surface•~12 half-blocks

Grout Core Fill: 0.19 yd³ (~9 bags)Est. Total: $350 - $458
Running Bond Wall Elevation6 Courses · 20 ft × 4 ft
Concrete Strip Footing20 ft Length4 ft
Red: Vertical #4 RebarStandard 8×8×16 CMU
🛡️
Wall Height Code: At 4.0 ft height, this wall is within standard 4-foot unengineered retaining/garden wall thresholds. Install clean gravel backfill and a perforated drain pipe to relieve hydrostatic pressure.
Type S/M Mortar3 bags80 lb bags
#4 Vertical Rebar9 bars~50 ft total
Strip Footing0.66 yd³~30 bags
Advertisement

Standard Concrete Masonry Unit (CMU) Sizing & Mortar Rules

Concrete masonry units are referred to by their nominal dimensions, which include a standard 3/8-inch mortar joint. An 8×8×16 block actually measures 7 5/8" wide by 7 5/8" high by 15 5/8" long.

Nominal Size (W×H×L)Face AreaBlocks / 100 Sq FtCore Volume / BlockTypical Application
6×8×16 Inch0.889 sq ft112.5 blocks0.16 cu ftLight interior partitions, storage sheds
8×8×16 Inch (Standard)0.889 sq ft112.5 blocks0.22 cu ftResidential retaining walls, foundation crawlspaces
12×8×16 Inch0.889 sq ft112.5 blocks0.33 cu ftHeavy earth retaining, deep basement perimeter walls

Mortar Selection: Type S vs Type N vs Type M

Mortar binds blocks together while accommodating slight thermal movement. Selecting the wrong mortar formulation can cause joint cracking or water intrusion:

Type S Mortar (Recommended)

1,800 PSI Compressive Strength

The standard industry recommendation for exterior retaining walls, below-grade foundation blocks, and walls subjected to high lateral soil loads or seismic activity. Provides excellent flexural bond strength.

Type N Mortar

750 PSI Compressive Strength

Medium-strength general purpose mortar used for above-grade exterior veneer and non-loadbearing interior partitions. Too flexible for heavy retaining walls holding back saturated soil.

Type M Mortar

2,500 PSI Compressive Strength

Highest compressive strength available, designed for heavy concentrated vertical structural loads, below-grade foundations with severe groundwater contact, and manholes.

Crucial Retaining Wall Construction Rules

1. Poured Concrete Strip Footing Rule

Never place concrete blocks directly on gravel or soil. Pour a solid concrete footing twice as wide as the block thickness (a 16-inch wide footing for standard 8" blocks) and at least 8 inches thick, reinforced with two continuous lines of #4 (1/2") steel rebar. Embed rebar dowels that project upward into the block cells.

2. Hydrostatic Pressure Relief (Drainage is 90% of Success)

Retaining walls don't fail from the weight of dry dirt—they fail from trapped hydrostatic water pressure. Backfill the immediate 12 inches behind the wall with #57 crushed clean stone, install a 4-inch perforated PVC drain pipe sloping to daylight at the footing base, and install 1.5" PVC weep holes every 6 to 8 feet along the bottom course.

3. The 4-Foot Height Permit Barrier

Under International Residential Code (IRC) Section AH106, retaining walls exceeding 4 feet in total height measured from the bottom of the footing to the top of the wall require an engineered design signed by a registered structural engineer, including soil geogrid reinforcement tie-backs.